16 kW Standby Generator Installation in Little Egg Harbor, NJ | Whole-House Backup

Little Egg Harbor, NJ · Client since August 2020

Claire from Little Egg Harbor, NJ has been a Green Sun Energy Services client since August of 2020. The generator was commissioned in January of 2021: 16 kW on natural gas, on a 200-amp service-entrance switch with two smart management modules, sized against a 13 kW calculation for the 1,890 square foot house. A double electric oven is the appliance doing most of the work in that number. Little Egg Harbor sits at the top of Great Bay behind Long Beach Island, in the part of Ocean County where a storm surge and a power cut tend to arrive together – and where the restoration crews have a good deal of ground to cover before they reach you. Annual maintenance, a ten-year extended parts-and-labor warranty and monitoring we manage all sit behind the machine.

Project Facts

Location
Little Egg Harbor, NJ
Services
Standby Generator Installation, Standby Generator Service
Client since
August 2020
Manufacturer
Generac Model # 7178
Rated output
16 kW LP / 16 kW NG
Fuel
Natural Gas
Home sized for
1,890 sq ft
Electrical service
200 amp
Transfer switch
200 amp
Load management
Managed Whole House

Standby generator questions from Little Egg Harbor homeowners

Does the transfer switch need flood protection as well as the generator?

Yes. A flood review should cover much more than the generator enclosure. FEMA recommends that a residential standby system consider elevation or protection of the generator, the transfer switch, the normal and emergency panels, the feeders and the control wiring together.

Can a standby generator be installed in the garage?

No. Residential air-cooled standby generators are designed for outdoor installation and must never be run inside a garage, basement, shed or any other enclosed occupied space. The engine produces carbon monoxide, which can cause serious injury or death. That is why outdoor location and separation from building openings are treated as critical rather than as preferences.

Does a 200-amp service need a 200-amp transfer switch?

A transfer switch installed in the service path has to be rated appropriately for the service and the configuration. A 200-amp service commonly uses a 200-amp service-rated switch, but the actual design is confirmed by the electrician rather than assumed from the service size.

Scroll to Top