Generac 17 kW Standby Generator in Farmingdale, NJ | Four Load Modules, 3,100 Sq. Ft.

17 kW Generac standby generator in Farmingdale, NJ
17 kW Generac standby generator in Farmingdale, NJ by Green Sun Energy Services.

Farmingdale, NJ · Client since February 2013

Gene and Lilli from Farmingdale, NJ have been Green Sun Energy Services clients since February of 2013. Gene and Lilli signed in early February and the generator was commissioned in the middle of June, a 17 kW Generac behind a service-rated switch with four load management modules. The modules are what let a 17 kW machine carry 3,100 square feet with two electric ovens, two refrigerators, a dishwasher and the laundry: the heavy loads take turns rather than competing. A PowerBase plan has covered it since. Farmingdale is in Monmouth County.

Project Facts

Location
Farmingdale, NJ
Services
Standby Generator Installation, Standby Generator Service
Client since
February 2013
Manufacturer
Generac Model # 6053-0
Rated output
17 kW LP / 16 kW NG
Fuel
Natural Gas
Home sized for
3,100 sq ft
Transfer switch
0 amp
Load management
Managed Whole House

They took care of everything including the permits. The entire process was flawless from the gentleman who came to explain everything, to the installer, to the final product. I have absolutely no complaints. They were always on time and cleaned up well. As issues can arise in any circumstance. They were quick and professional to address and move forward. I would highly recommend their service.

— Gene and Lilli2013Reviewed us onAngi

Green Sun Energy Services replied

Thank you, Gene. Taking care of the permits is not a favor, it is the job: a standby generator in Farmingdale needs gas, electrical and township sign-off before it is worth anything. The 17 kW machine covers three thousand one hundred square feet using four load modules, which is how a house that size stays on one generator.

Standby generator questions from Farmingdale homeowners

Will a larger gas meter be needed?

Possibly. A generator can significantly increase a home's maximum gas demand. If the existing meter or service cannot hold the required pressure while supplying the generator and the other appliances together, the gas utility may require an upgrade.

Why can't a generator be wired straight into the panel?

Because a standby generator needs approved transfer or interconnection equipment so that it cannot unintentionally energise the utility supply. The transfer switch is one of the most important electrical-safety components in the whole installation, not an accessory to it.

What size standby generator does a Farmingdale home need?

The correct size is decided by the electrical loads the generator is expected to run, not by the square footage of the house. Central air, heat pumps, electric heat, well and sump pumps, refrigerators and freezers, electric ranges and dryers, pool equipment and EV chargers all count. Where a load is connected automatically, the generator either has the capacity for it or an approved load-management system controls it.