Robert and Anne Marie in New Providence have been Green Sun Energy Services clients since May of 2016. They signed for the solar array and the standby generator on the same day; the array was commissioned in July 2016 and the generator three weeks later.
38 panels, 11.97 kW
Thirty-eight LG 315-watt panels, 11.97 kW in total, spread across several roof faces on QuickMount rails, with a SolarEdge SE10000A inverter and a P320 optimizer on every panel. Estimated first-year production is 13,364 kWh and the utility is JCP&L.
The faces are not equal. Two of them run at 95 and 97 percent of what the orientation would ideally give; a third runs at 73. Per-panel optimizers are what make that acceptable — each group performs to its own conditions instead of the whole system being pulled toward the weakest one, which is the arrangement a conventional string inverter would have produced.
A 16 kW machine three weeks later
The generator is a Generac 16 kW in a steel enclosure, model 6462, rated 16 kW on natural gas and on propane alike, behind a 200-amp service-rated transfer switch with two power management modules. The house is 3,000 square feet, its electrical calculation comes to 20,480 watts, and 6,000 watts of air conditioning is managed while the generator runs, leaving 14,480 to carry. It was last serviced on 13 July 2026.
The pipes are the real risk
The heating in this house runs on gas, and it still stops the moment the electricity does. A gas furnace needs power for its blower, its igniter and its controls; without them it is an inert box in the basement with a perfectly good fuel supply arriving at it.
That matters more in January than any other fact on this page. A summer outage is uncomfortable and expensive — the food goes, the house is hot, nobody sleeps well. A winter outage in northern New Jersey is a different category of problem, because the house does not merely become unpleasant. It begins cooling toward the outside temperature, and if the outage runs long enough and the temperature is low enough, the water in the pipes starts to freeze.
Frozen plumbing is the failure that turns a two-day inconvenience into months of repair work. Pipes do not usually burst while frozen; they burst on thawing, often in a wall or a ceiling, and often while the household is still away waiting for the power to come back. It is the one outage consequence that keeps costing money after the lights are on.
Backup power ends that risk entirely, and it does it by keeping something quite small running: a blower motor and a control board. The solar array on the roof, for all its 11.97 kilowatts, contributes nothing — a grid-tied system shuts down when the utility fails, and must, so that it cannot energise a line a crew is working on. On the coldest night of the year the useful machine is the one beside the house.
Project Facts
- Location
- New Providence, NJ
- Services
- Solar Panel Installation, Standby Generator Installation, Standby Generator Service
- Client since
- May 2016
Solar
- Panels
- LG Model # 315N1K-G4/40mm
- Panels
- 38
- System size
- 11.97 kW
- Inverter
- SolarEdge SE10000A-US000NNR2 Inverter (25Y) W/ P320 HD Wave
- Mounting system
- QuickMount
- Estimated first-year production
- 13,364 kWh
- Share of the home's electricity
- 69%
- Electric utility
- JCP&L
Standby generator
- Manufacturer
- Generac Model # 6462
- Rated output
- 16 kW LP / 16 kW NG
- Fuel
- Natural Gas
- Home sized for
- 3,000 sq ft
- Electrical service
- 200 amp
- Transfer switch
- 200 amp
- Load management
- Managed Whole House
Questions from New Providence homeowners
SolarWhat is hosting capacity, and can it affect a New Providence property?
Hosting capacity is how much distributed generation a part of the grid can take without affecting safety or reliability. A neighborhood with a lot of existing solar can face interconnection limits even where the individual property is ideal for it -- which is why the utility review is not a formality.
Standby generatorHow far does a generator have to be from a window or door?
Manufacturer guidance requires substantial separation from operable windows, doors, vents and other openings through which exhaust could enter the house -- commonly five feet for the applicable air-cooled configurations. The exact model's current installation manual has to be checked before a location is approved.
SolarWho receives the certificates on a leased system?
That depends on the lease or power purchase agreement. Where solar is third-party owned, the system owner commonly retains the renewable-energy certificates and related incentives because it owns the generating equipment. The contract should say explicitly who owns the environmental attributes.