Standby Generator Installation in Colts Neck, NJ | A 22 kW Generac on a 200-Amp Switch

22 kW Generac standby generator in Colts Neck, NJ
22 kW Generac standby generator in Colts Neck, NJ by Green Sun Energy Services.

Colts Neck, NJ · Client since February 2021

Scott and Lanie from Colts Neck, NJ have been Green Sun Energy Services clients since February of 2021. The machine is a Generac 7043-2 rated 22 kW on propane and 19.5 kW on natural gas, running on natural gas, on a 200-amp transfer switch, and it was commissioned in August of 2021. At about 2,100 square feet with the whole panel transferring, nothing here is set aside for an outage. Green Sun serviced it in September of 2022, September of 2023 and June of 2025.

Why Scott and Lanie chose Green Sun Energy Services

Complete backup power, from sizing and installation to the service that keeps it ready.

What makes Green Sun Energy Services different

  • Standby generators: installed and serviced as a Generac Authorized Sales and Service Dealer, by factory-authorized Generac technicians. On this home: a Generac 7043-2 standby generator (22 kW LP / 19.5 kW NG) running on natural gas, on a 200-amp transfer switch (managed whole house).
  • Warranty: backed by a 1-year generator workmanship warranty.
  • Local: locally owned and operated in New Jersey since 2010, NJHIC licensed (#13VH06229000), with 438 completed standby generator projects across Monmouth County and 614 standby generator projects throughout New Jersey.

Our work in Colts Neck

Green Sun Energy Services has completed 16 standby generator installations in Colts Neck. Colts Neck, a township in Monmouth County, is served by JCP&L.

A generator is only valuable if it's ready when the power goes out.

Thinking about a standby generator for your Colts Neck home? Tell us about your project here or call 732-410-7818.

Power it. Protect it. Maintain it.

Project Facts

Location
Colts Neck, NJ
Service
Standby Generator Installation
Client since
February 2021
Manufacturer & model
Generac 7043-2
Rated output
22 kW LP / 19.5 kW NG
Fuel
Natural Gas
Home sized for
2,100 sq ft
Electrical service
200 amp
Transfer switch
200 amp
Load management
Managed Whole House
Workmanship warranty
1 year

Standby generator questions from Colts Neck homeowners

Can a fence be put around the generator?

Potentially, but a fence cannot encroach on the required airflow, exhaust and service clearances. A removable screening panel suits some installations, though technicians still need room to open the machine and work on it safely. Local zoning may separately require or regulate screening.

How deep does the electrical conduit have to be buried?

It depends on the wiring method and the location; there is no single burial depth for every installation. The National Electrical Code governs underground wiring and sets minimum cover in a table, and the conduit type, the location and the physical protection all change the answer.

Can the existing natural-gas service in a Colts Neck home supply a generator?

Often yes, but the gas system has to be evaluated first. The review covers the generator's BTU demand, meter capacity, available pressure, regulator capacity, pipe diameter and length, and every other gas appliance in the house -- furnace, boiler, water heater, range and fireplace among them.