Standby Generator Installation in Tinton Falls, NJ | A 22 kW Generac, Client Since 2020

22 kW Generac standby generator in Tinton Falls, NJ
22 kW Generac standby generator in Tinton Falls, NJ by Green Sun Energy Services.

Tinton Falls, NJ · Client since August 2020

Ron and Linda from Tinton Falls, NJ have been Green Sun Energy Services clients since August of 2020. The machine is a Generac 7042-2 rated 22 kW on propane and 19.5 kW on natural gas, running on natural gas, on a 150-amp transfer switch, and it was commissioned in March of 2021. The house is about 2,900 square feet. Green Sun has serviced it every year since – January of 2022, February of 2023, March of 2024, February of 2025 and February of 2026 – and it reports to remote monitoring in between, so a fault announces itself rather than waiting to be found.

Why Ron and Linda chose Green Sun Energy Services

Complete backup power, from sizing and installation to the service that keeps it ready.

What makes Green Sun Energy Services different

  • Standby generators: installed and serviced as a Generac Authorized Sales and Service Dealer, by factory-authorized Generac technicians. On this home: a Generac 7042-2 standby generator (22 kW LP / 19.5 kW NG) running on natural gas, on a 150-amp transfer switch (managed whole house) and serviced by Green Sun Energy Services.
  • Warranty: backed by a 5-year generator workmanship warranty.
  • Local: locally owned and operated in New Jersey since 2010, NJHIC licensed (#13VH06229000), with 444 completed standby generator projects across Monmouth County and 621 standby generator projects throughout New Jersey.

Our work in Tinton Falls

Green Sun Energy Services has completed 10 standby generator installations and 21 generator service customers in Tinton Falls. Tinton Falls, a borough in Monmouth County, is served by JCP&L.

Thinking about a standby generator for your Tinton Falls home? Tell us about your project here or call 732-410-7818.

Power it. Protect it. Maintain it.

Project Facts

Location
Tinton Falls, NJ
Services
Standby Generator Installation, Standby Generator Service
Client since
August 2020
Manufacturer & model
Generac 7042-2
Rated output
22 kW LP / 19.5 kW NG
Fuel
Natural Gas
Home sized for
2,900 sq ft
Electrical service
150 amp
Transfer switch
150 amp
Load management
Managed Whole House
Workmanship warranty
5 years

Standby generator questions from Tinton Falls homeowners

Does a permanently installed generator need a disconnect?

Yes. Permanently installed generators fall under the disconnecting-means requirements of the National Electrical Code's generator article, and the equipment and electrical design have to satisfy those requirements alongside the machine's own listing and instructions.

Can the existing natural-gas service in a Tinton Falls home supply a generator?

Often yes, but the gas system has to be evaluated first. The review covers the generator's BTU demand, meter capacity, available pressure, regulator capacity, pipe diameter and length, and every other gas appliance in the house -- furnace, boiler, water heater, range and fireplace among them.

Can Tinton Falls require a generator to sit farther from the house than the manufacturer does?

Yes. Another applicable requirement can result in greater separation than the manufacturer's listed minimum -- equipment may be permitted eighteen inches from a qualifying wall while the local ordinance requires several feet from a property line. Both requirements have to be satisfied; neither cancels the other.