Mike from Middletown, NJ has been a Green Sun Energy Services client since January of 2021. The generator was commissioned that August: 14 kW on natural gas, on a 200-amp service-entrance switch with a smart management module, sized against a 15 kW calculation for the 2,442 square foot house. Two heat pumps are what put the calculated figure above the machine, and the management module is what reconciles the two – each compressor draws several times its running load in the instant it starts, and the module makes sure they never do it together. Bollards were agreed in advance as the household’s responsibility if the township required them, which is the sort of condition worth settling before the work rather than during it. Annual maintenance, a ten-year extended parts-and-labor warranty and monitoring we manage all sit behind the machine.

Project Facts

Location
Middletown, NJ
Services
Standby Generator Installation, Standby Generator Service
Client since
January 2021
Manufacturer
Generac Model # 7225
Rated output
14 kW LP / 14 kW NG
Fuel
Natural Gas
Electrical service
200 amp
Transfer switch
200 amp
Load management
Managed Whole House

Standby generator questions from Middletown homeowners

Can a generator be installed in a flood zone in Middletown?

Yes, but the generator and its electrical equipment may need to be elevated or otherwise protected. The installation is evaluated against the property's FEMA flood zone, its Base Flood Elevation and Design Flood Elevation, the municipal flood ordinance, any applicable freeboard, and NJDEP requirements where they apply. It is a property-by-property assessment rather than a rule of thumb.

Will a 22 kW generator run an entire Middletown house?

For many homes, yes, but that does not mean every load can run at the same moment. Houses with two central air conditioners, electric heat, EV charging, pool equipment or electric cooking may need load management or a larger machine. The answer comes from a load calculation rather than from the phrase whole house.

Should gas pressure be checked while the generator is running?

Yes. Operating pressure means more than a static reading taken with the generator off. The fuel system has to hold adequate pressure while the generator runs and other appliances may also be drawing gas. That matters most when an existing residential service is being reused.