Standby Generator Installation in Mantoloking, NJ | A Noise Limit That Set the Generator Size

Mantoloking, NJ · Client since April 2023

Shelley from Mantoloking, NJ has been a Green Sun Energy Services client since April of 2023. The generator was commissioned in February of 2024: 18 kW on natural gas, on a 200-amp service-entrance switch with three smart management modules and surge protection. The size was decided by the township rather than by the load calculation. Mantoloking permits no more than 65 decibels at the property line, and where a 22 kW machine measures 67, the 18 kW measures 65 – so the smaller machine was the only one that could be installed. The calculation asked for 16 kW across the 3,400 square foot house, so the 18 kW still covers it, and the three management modules do the work a larger machine would otherwise have done. Annual maintenance, an extended parts-and-labor warranty and monitoring we manage all sit behind it.

Project Facts

Location
Mantoloking, NJ
Services
Standby Generator Installation, Standby Generator Service
Client since
April 2023
Manufacturer
Generac Model # 7226
Rated output
18 kW LP / 17 kW NG
Fuel
Natural Gas
Home sized for
3,400 sq ft
Electrical service
200 amp
Transfer switch
200 amp
Load management
Managed Whole House

Standby generator questions from Mantoloking homeowners

What size standby generator does a Mantoloking home need?

The correct size is decided by the electrical loads the generator is expected to run, not by the square footage of the house. Central air, heat pumps, electric heat, well and sump pumps, refrigerators and freezers, electric ranges and dryers, pool equipment and EV chargers all count. Where a load is connected automatically, the generator either has the capacity for it or an approved load-management system controls it.

Does the generator start on its own?

Yes. A properly installed standby generator left in AUTO is designed to start automatically when it detects an unacceptable loss of utility power. The transfer system then moves the household loads across, and when acceptable utility power returns it transfers them back and the generator runs through its programmed shutdown.

Does the generator have to be bolted down?

Not every ground-level installation uses the same anchoring method. The requirement changes with the model, the pad type, wind exposure, flood requirements, elevated platforms and any local engineering requirement. The model manual and the site conditions decide it.