Generator, Solar and Soft Washing in Piscataway

Piscataway, NJ · Client since August 2025

Francis from Piscataway, NJ has been a Green Sun Energy Services client since August of 2025, and took three trades inside twelve months.

A 14 kW Generac on a 100-amp service

Running by 24 October 2025. The calculation asked for a minimum of 12 kW under NEC Article 220 Part IV and a 14 kW Generac went in on natural gas, on a composite pad, behind a 100-amp service-rated managed whole-house transfer switch with a load-management module and whole-house surge protection. Everything here is scaled to a compact house: 1,548 square feet, a refrigerator, a dishwasher, a washer and a gas dryer, on a 100-amp service. A service-rated switch matched to 100 amps rather than the more common 200 is the right answer rather than a lesser one – the switch is sized to the service the house actually has. The machine is on our Diamond plan: annual maintenance, extended parts-and-labor cover and remote monitoring that Green Sun runs directly.

12 panels and 5.16 kW

A month later, on 21 November: 12 Jinko 430-watt modules with Enphase IQ8PLUS microinverters, rail-mounted, 5.16 kW rated and estimated at 5,345 kilowatt hours in the first year. Seventy-two feet of critter guard runs the full perimeter, which it would whatever the array’s size – a small array leaves exactly the same inviting gap underneath as a large one, and the wiring up there costs the same to repair either way. The roof needed nothing. The monitoring gateway is mounted outdoors, immediately beside the generator’s transfer switch.

5,747 square feet of soft washing

May of 2026. Soft washing is low pressure and a cleaning solution rather than a pressure washer, which lifts algae and mildew off siding without driving water in behind it.

Two systems, a few feet apart, doing opposite jobs

The array and the generator ended up on the same wall, and the pairing is worth more on a service this size than on a large one. On an ordinary day the panels reduce what a 100-amp service has to deliver to the house. During an outage they contribute nothing at all – a grid-tied array shuts down with the grid, so that no house is feeding power into lines somebody may be working on – and the generator supplies the house instead. Neither substitutes for the other. On 100 amps there is simply less headroom to waste, so the thing that lowers demand and the thing that replaces supply are both working against a tighter number, and both were specified by people who knew the other was coming.

Glen and his team did a Generac generator and a Solar System installation for me. The team did an absolutely fantastic job throughout the entire process. They are very reliable, walk you through all the details step by step, communicated clearly, and completed the work on time. They will help you through design, permits, inspections, various registrations. If you need it, they can help with financing and suggest best options. They are in for the long haul and are more interested in maintaining a relationship with their customers. They are easy to work with. I highly recommended that you consider Green Sun Energy for your generator and solar system acquisition, deployment and ongoing support.

— Francis2025Reviewed us onGoogle

Green Sun Energy Services replied

Thank you, Francis. A generator and a solar array at one house in Piscataway involve different trades, different inspections and different timelines, so being walked through it step by step is what keeps a long project from feeling chaotic. Reliable is the word we would most like to keep.

Why Francis chose Green Sun Energy Services

Clean the cause, not just the surface, without blasting your home with unnecessary pressure.

More than solar panels: a professionally managed energy system, from design and permitting through installation, inspection, activation and ongoing support.

Complete backup power, from sizing and installation to the service that keeps it ready.

What makes Green Sun Energy Services different

  • Soft washing: cleaned by a team trained in soft washing, using the right cleaning solution and low pressure for each surface. Fully licensed and insured. On this home: a soft wash of 5,747 sq ft.
  • Solar: design and installation supervised by a NABCEP-certified professional (#PVA-111016-016148), with Enphase microinverters on every panel so each one reports its own output. On this home: a 5.16 kW solar array of 12 Jinko JKM430N-54HL4R-B panels, an EnPhase IQ8PLUS-72-M-US Micro-Single inverter, the Unirac mounting system and 72 ft of critter guard.
  • Standby generators: installed and serviced as a Generac Authorized Sales and Service Dealer, by factory-authorized Generac technicians. On this home: a Generac 7258 standby generator (14 kW LP / 14 kW NG) running on natural gas, on a 100-amp transfer switch (managed whole house) and serviced by Green Sun Energy Services.
  • Warranty: backed by a 10-year solar workmanship warranty and a 5-year generator workmanship warranty.
  • Local: locally owned and operated in New Jersey since 2010, NJHIC licensed (#13VH06229000), with completed soft wash projects, 48 completed solar projects and 36 completed standby generator projects across Middlesex County and 46 soft wash projects, 361 solar projects and 621 standby generator projects throughout New Jersey.

Our work in Piscataway

Green Sun Energy Services has completed 1 soft wash, 6 featured solar projects, 3 standby generator installations and 6 generator service customers in Piscataway. Piscataway, a township in Middlesex County, is served by PSE&G.

Generate electricity on your roof and use it to help power your vehicle.

Thinking about solar, a standby generator, or a soft wash for your Piscataway home? Tell us about your project here or call 732-410-7818.

Power it. Protect it. Maintain it.

Project Facts

Location
Piscataway, NJ
Services
Softwash Service, Solar Critter Guard, Solar Panel Installation, Standby Generator Installation, Standby Generator Service
Client since
August 2025

Solar

Manufacturer & model
Jinko JKM430N-54HL4R-B
Panels
12
System size
5.16 kW
Inverter
EnPhase IQ8PLUS-72-M-US Micro-Single
Mounting system
Unirac
Estimated first-year production
5,345 kWh
Share of the home's electricity
99%
Electric utility
PSE&G
Critter guard fitted
72 ft
Workmanship warranty
10 years

Standby generator

Manufacturer & model
Generac 7258
Rated output
14 kW LP / 14 kW NG
Fuel
Natural Gas
Home sized for
1,548 sq ft
Electrical service
100 amp
Transfer switch
100 amp
Load management
Managed Whole House
Workmanship warranty
5 years

Exterior cleaning

Surface cleaned
5,747 sq ft

Questions from Piscataway homeowners

Standby generatorCan the existing natural-gas service in a Piscataway home supply a generator?

Often yes, but the gas system has to be evaluated first. The review covers the generator's BTU demand, meter capacity, available pressure, regulator capacity, pipe diameter and length, and every other gas appliance in the house -- furnace, boiler, water heater, range and fireplace among them.

Standby generatorWhich fuel-gas code applies?

New Jersey currently adopts the 2024 International Fuel Gas Code as its Fuel Gas Subcode, which is what governs the piping, testing and shutoff arrangements on a natural-gas generator installation.

Standby generatorWhat actually gets done at a service visit?

It depends on the model, the age and the interval, but typically engine oil and filter, air filter, spark plug inspection or replacement, battery inspection, a fuel-system leak check, sediment-trap inspection, valve clearance where applicable, and inspection of the enclosure and intakes.

Soft washingWill the roof look completely clean the same day?

Algae staining can improve rapidly, but moss and lichen may take longer to weather away after treatment. The objective is to clean the roof safely, not to achieve an instant cosmetic result by damaging the shingles.

Soft washingCan composite decking be cleaned?

Yes, but the decking manufacturer's own cleaning instructions govern. Composite products differ considerably in what cleaning products, pressures and nozzles they permit, and in how they should be treated for stains. The instructions for the actual product are the authority, not a general rule about composites.

SolarWhich direction should the panels face?

South-facing roof planes generally give excellent annual production, but east and west can be very productive too. The design should compare the modelled annual production of each available plane rather than rejecting anything that is not due south.

SolarDo unused credits carry from month to month?

Yes. Eligible excess kWh credits generally carry through the customer's annualised net-metering period, which is what allows strong spring and summer production to offset consumption in the darker months.

Scroll to Top