A 22 kW Generac standby generator service plan:
Thomas in Middletown, NJ has a Generac 22 kW standby generator — Model 7042 from the 7000 Series — running on natural gas with a 100-amp automatic transfer switch configured for whole-house coverage. When JCP&L power goes out, the transfer switch detects the outage and starts the generator automatically, moving the full house load over without Thomas having to do anything.
Green Sun Energy Services did not install the generator, but took over its care and now handles scheduled maintenance and remote Wi-Fi monitoring. The monitoring lets the team track the generator’s status between visits and catch anything that needs attention before it becomes a problem. Maintenance visits follow a set schedule so the unit stays ready when it matters.
The service plan also carries an extended parts-and-labor warranty, which means covered repairs on the generator are handled without Thomas having to source a contractor or negotiate coverage separately.
Why Middletown homeowners choose Green Sun Energy Services
We keep your generator ready before the power goes out.
What makes Green Sun Energy Services different
- Standby generators: installed and serviced as a Generac Authorized Sales and Service Dealer, by factory-authorized Generac technicians. On this home: a standby generator serviced by Green Sun Energy Services.
- Local: locally owned and operated in New Jersey since 2010, NJHIC licensed (#13VH06229000), with 708 completed generator service projects across Monmouth County and 936 generator service projects throughout New Jersey.
Our work in Middletown
Green Sun Energy Services has completed 120 generator service customers in Middletown. Middletown, a township on Raritan Bay and Sandy Hook Bay in Monmouth County, is served by JCP&L.
Thinking about generator service for your Middletown home? Tell us about your project here or call 732-410-7818.
Power it. Protect it. Maintain it.
Project Facts
- Location
- Middletown, NJ
- Service
- Standby Generator Service
- Client since
- September 2021
- Manufacturer & model
- Generac 7042
- Rated output
- 22 kW LP / 19.5 kW NG
- Fuel
- Natural Gas
- Transfer switch
- 100 amp
- Load management
- Whole House
Standby generator questions from Middletown homeowners
Can a generator be raised on a platform?
Yes. Manufacturer guidance specifically covers installations on platforms and other supporting structures, and directs them to the applicable fire-safety standard, including a noncombustible surface extending beyond the generator for the configuration addressed. Flood and structural requirements have to be satisfied as well.
Does the transfer switch need flood protection as well as the generator?
Yes. A flood review should cover much more than the generator enclosure. FEMA recommends that a residential standby system consider elevation or protection of the generator, the transfer switch, the normal and emergency panels, the feeders and the control wiring together.
Will the sump pump keep working if the power goes out?
It will if it is on the generator. This matters most in exactly the weather that causes outages: heavy rain and a power cut tend to arrive together, and a sump pump without power cannot keep a basement dry. A sump pump is one of the loads worth confirming during the survey rather than assuming.