Paul from Middletown, NJ has been a Green Sun Energy Services client since July of 2021. The generator was commissioned in February of 2022: 18 kW on natural gas, on a 200-amp managed whole-house switch, sized against a 14 kW calculation for the 2,800 square foot house. A refrigerator, a washer, a gas dryer and a dishwasher make up the load, so the machine carries a comfortable margin over what the calculation required. One condition was agreed before the work: three large bushes removed from the proposed generator position by the household. Annual maintenance, an extended parts-and-labor warranty and monitoring we manage all sit behind the machine.

Project Facts

Location
Middletown, NJ
Services
Standby Generator Installation, Standby Generator Service
Client since
July 2021
Manufacturer
Generac Model # 7228
Rated output
18 kW LP / 17 kW NG
Fuel
Natural Gas
Home sized for
2,800 sq ft
Electrical service
200 amp
Transfer switch
200 amp
Load management
Managed Whole House

Standby generator questions from Middletown homeowners

What is a service-entrance-rated transfer switch?

One that is listed for use as service equipment when installed in the appropriate configuration. These are commonly used for whole-house systems, where the transfer switch becomes part of the home's service arrangement rather than sitting downstream of it.

What is a sediment trap for?

It helps stop foreign material in the gas line from reaching the generator's fuel controls. Where the fuel-gas code and the system configuration call for one, it is fitted, and the maintenance schedule includes inspecting or cleaning it.

Can a generator be installed on a deck or a roof?

Platform, deck and supporting-structure installations are recognized, but they call for additional review: structural capacity, noncombustible surface requirements, fire clearance, exhaust, airflow, vibration, service access and local requirements all have to be addressed. It is a site-specific installation rather than a routine location.