20 kW Standby Generator Service in Atlantic Highlands, NJ | Generac Generator

Atlantic Highlands, NJ · Client since February 2022

Hilary from Atlantic Highlands, NJ has been a Green Sun Energy Services client since February of 2022. The generator was installed by another company and commissioned in July of 2011, and the servicing came to us more than ten years later, beginning with a startup inspection to establish what condition it was actually in. The ten-year service has been carried out every year since – 2023, 2024 and again after that. A machine in its fifteenth year is well beyond the age at which most standby generators have been quietly written off, and the only thing separating one that still starts from one that does not is whether somebody keeps opening the enclosure. An annual maintenance plan covers the visit, with the manufacturer’s standard warranty behind the machine.

Why Hilary chose Green Sun Energy Services

We keep your generator ready before the power goes out.

What makes Green Sun Energy Services different

  • Standby generators: installed and serviced as a Generac Authorized Sales and Service Dealer, by factory-authorized Generac technicians. On this home: a standby generator serviced by Green Sun Energy Services.
  • Local: locally owned and operated in New Jersey since 2010, NJHIC licensed (#13VH06229000), with 709 completed generator service projects across Monmouth County and 937 generator service projects throughout New Jersey.

Our work in Atlantic Highlands

Green Sun Energy Services has completed 27 generator service customers in Atlantic Highlands. Atlantic Highlands, a borough on Sandy Hook Bay in Monmouth County, is served by JCP&L.

Thinking about generator service for your Atlantic Highlands home? Tell us about your project here or call 732-410-7818.

Power it. Protect it. Maintain it.

Project Facts

Location
Atlantic Highlands, NJ
Service
Standby Generator Service
Client since
February 2022
Manufacturer & model
Generac 5887
Rated output
20 kW LP / 18 kW NG
Fuel
Natural Gas
Transfer switch
90 amp
Load management
Managed Whole House

Standby generator questions from Atlantic Highlands homeowners

Does new gas piping have to be pressure tested in Atlantic Highlands?

Yes. Gas piping subject to the adopted fuel-gas code must be inspected and tested before it is accepted. New Jersey adopts the 2024 International Fuel Gas Code, which governs the inspection, the test pressure and how long the test has to hold.

Can a standby generator run central air conditioning?

Yes, when it is sized for it. The design has to account for both the running demand and the starting surge of the air-conditioning equipment. Load-management equipment can be used where necessary so that demand does not all arrive at once.

Does the clearance apply to a fixed window as well as one that opens?

A permanently fixed pane may be treated differently from an operable window, because the concern in the placement guidance is exhaust and carbon monoxide entering the building. Even so, the installer has to evaluate the exact model's manual and everything nearby -- operable windows, doors, vents, fresh-air intakes, window wells and mechanical openings. A fixed window should never simply be assumed acceptable.