Solar Panel Installation and Roofing Installation in Princeton, NJ | A 4,100 Square Foot Roof and 22 Panels

Princeton, NJ · Client since June 2022

Samir Hanna came to Green Sun Energy Services as a referral and has been a client since June of 2022, when the roof and the solar array were bought on the same day. The roof was finished on 2 November 2022 and the array eight days later.

4,100 square feet, stripped to the deck

A single layer of old shingles came off to the sheathing and left with the dumpster. Deck protection went over the exposed sheathing, then a GAF Timberline HDZ system in Charcoal carrying a 50-year warranty, aluminum drip edge along 403 feet of rakes, eaves and valleys, and a ridge vent along the peak.

22 panels and 8.03 kW

Twenty-two REC 365 watt panels came to 8.03 kW on Snap-N-Rack mounting, finished on 10 November 2022, running into a SolarEdge SE7600H HD Wave inverter with an optimizer on every panel. PSE&G is the utility and the first year was designed for about 10,300 kWh — close to 1,300 kWh for every kilowatt installed, which is a well-oriented roof doing what it should.

Monitoring on a cable, not on the wireless

The inverter reports over Ethernet rather than the house wireless. It is a small thing at installation and it is the difference between monitoring that is still working in three years and monitoring that quietly stopped the day somebody changed the wireless password. A system nobody can see is a system nobody notices has a fault.

Why the roof went first

Eight days separated the two jobs. An array is fastened to a roof for twenty-five years and more, so shingles near the end of their life underneath one are a second job with a date already on them — panels off, roof on, panels back. Buying both together settled it in advance, and the panels went onto a roof one week old with a 50-year system beneath them.

Project Facts

Location
Princeton, NJ
Services
Roofing Installation, Solar Critter Guard, Solar Panel Installation
Client since
June 2022

Solar

Panels
REC Model # REC-365NP2-Black
Panels
22
System size
8.03 kW
Inverter
SolarEdge SE7600H-US000NNC2 HD Wave
Mounting system
Snap-N-Rack
Estimated first-year production
10,300 kWh
Share of the home's electricity
99%
Electric utility
PSE&G
Critter guard fitted
174 ft

Roof

System
GAF Timberline Lifetime Roofing System
Area replaced
4,100 sq ft
Warranty
50 years

Questions from Princeton homeowners

SolarDoes Princeton decide whether the installation is code-compliant?

The municipal construction department reviews and inspects the work under the Uniform Construction Code, but the substantive electrical requirements come from the statewide Electrical Subcode rather than from local preference. Municipalities may also administer zoning requirements where those apply.

RoofingCan a roof warranty transfer to a new owner?

Certain warranties can, subject to that warranty's own conditions and a required notification procedure with its own time limit. It is worth knowing the process before the house goes on the market rather than during the sale, and a transferable warranty is a genuine selling point.

RoofingCan too many roof vents cause problems?

Yes. Mixing incompatible exhaust systems can disrupt airflow and cause one vent to pull air through another instead of through the soffits. The goal is balanced intake and exhaust that follows the roof and attic design.