Johanna from Red Bank, NJ has been a Green Sun Energy Services client since April of 2023. Three jobs followed inside seven months: we took over the servicing of a generator another company had installed, fitted an EV charger in September, and commissioned an 11.34 kW array in October.
A generator we did not install
The machine is a Generac model 70432, rated 22 kW on propane and 19.5 kW on natural gas, and it was already on the property when Johanna switched the servicing to us. Four services have been completed between 2023 and 2025, the most recent with 37 hours on the meter.
A ChargePoint charger
A ChargePoint CPH50 went in that September, on the J1772 connector, drawing up to 11.5 kW from the home’s 200-amp service.
11.34 kW of solar
Twenty-seven REC 420-watt panels went up in October on a Snap-N-Rack mounting system, with 196 feet of critter guard fitted around the array to keep squirrels out from underneath. The modeling put first-year production at 14,283 kWh.
How the three fit together
A grid-tied array stops producing the moment the grid goes down, which is the gap the generator covers. The charger was already installed when the array went up a month later, so the car’s demand was a known figure on the roof rather than a projection.
Project Facts
- Location
- Red Bank, NJ
- Services
- EV Charger Installation, Solar Critter Guard, Solar Panel Installation, Standby Generator Service
- Client since
- April 2023
Solar
- Panels
- REC Model # 420AA-PURE-R
- System size
- 11.34 kW
- Inverter
- SolarEdge SE10000H-USNBBL14 HD Wave Energy Hub
- Mounting system
- Snap-N-Rack
- Estimated first-year production
- 14,283 kWh
- Critter guard fitted
- 196 ft
Standby generator
- Manufacturer
- Generac Model # 70432
- Rated output
- 22 kW LP / 19.5 kW NG
- Electrical service
- 200 amp
- Transfer switch
- 100 amp
EV charger
- Charger
- ChargePoint Model # CPH50-NEMA6-50-L23
- Charging port
- CCS (J1772)
- Circuit breaker
- 60 amp
- Estimated range added per hour
- Estimated Range Per Hour: 36 mi / 58 km
Questions from Red Bank homeowners
Standby generatorCan a generator be installed in a flood zone in Red Bank?
Yes, but the generator and its electrical equipment may need to be elevated or otherwise protected. The installation is evaluated against the property's FEMA flood zone, its Base Flood Elevation and Design Flood Elevation, the municipal flood ordinance, any applicable freeboard, and NJDEP requirements where they apply. It is a property-by-property assessment rather than a rule of thumb.
SolarHow does an optimizer system differ from microinverters?
An optimizer system puts DC power optimizers at the modules and a single central inverter elsewhere; a microinverter system puts a small inverter at each module. Both can provide module-level monitoring and rapid shutdown when properly designed -- they are different architectures rather than one being the upgrade of the other.
EV chargingCan a ChargePoint Home Flex be set lower if the panel is full?
Yes -- that is the point of the adjustable output. A house that cannot carry 48-amp charging might run at 32 amps on a 40-amp circuit, or 24 amps on a 30-amp one, where the load calculation and the installation support it.
EV chargingCan a ChargePoint charger charge a Tesla?
Yes. ChargePoint offers Home Flex with either a J1772 or a NACS connector. The NACS version connects directly to compatible Tesla vehicles, and the J1772 version charges a Tesla through the adapter Tesla supplies.
