Andy from Neptune, NJ has been a Green Sun Energy Services client since April of 2021. Two jobs three years apart, and the second one is easier because of the first.
An 18 kW standby generator
A Generac 7226 rated 18 kW on propane and 17 kW on natural gas, running on natural gas, on a 150-amp transfer switch, commissioned in January of 2022. The house is about 2,000 square feet. Green Sun has serviced it in January of 2023, February of 2024, January of 2025 and January of 2026, and it reports to remote monitoring in between.
An EV charger
A ChargePoint Home Flex, hardwired rather than plugged in, on a 60-amp circuit, finished in January of 2025. It delivers around 11.5 kW through a J1772 connector. The load calculation put the minimum service panel at about 149 amps.
Why the order helped
A charger is one of the largest loads a house can add, and a standby system has already had the service looked at properly once. The panel, the loads and what the house actually draws at once were all documented from the generator job, so the charger was a question of capacity rather than a survey from scratch.
Why Andy chose Green Sun Energy Services
Professional home EV charging made simple, from electrical design through final inspection.
Complete backup power, from sizing and installation to the service that keeps it ready.
What makes Green Sun Energy Services different
- EV charging: installed with certifications from Qmerit, ChargePoint, Enphase, SolarEdge and Tesla, by a licensed electrician and fully managed by our team. On this home: a ChargePoint CPH50-HARDWIRE-L23 EV charger on a 60-amp circuit.
- Standby generators: installed and serviced as a Generac Authorized Sales and Service Dealer, by factory-authorized Generac technicians. On this home: a Generac 7226 standby generator (18 kW LP / 17 kW NG) running on natural gas, on a 150-amp transfer switch (managed whole house) and serviced by Green Sun Energy Services.
- Warranty: backed by a 5-year generator workmanship warranty.
- Local: locally owned and operated in New Jersey since 2010, NJHIC licensed (#13VH06229000), with 35 completed EV charger projects and 441 completed standby generator projects across Monmouth County and 91 EV charger projects and 618 standby generator projects throughout New Jersey.
Our work in Neptune
Green Sun Energy Services has completed 1 EV charger installation, 3 standby generator installations and 3 generator service customers in Neptune. Neptune, a township on the Atlantic Ocean in Monmouth County, is served by JCP&L.
Thinking about a standby generator, an EV charger, or both for your Neptune home? Tell us about your project here or call 732-410-7818.
Power it. Protect it. Maintain it.
Project Facts
- Location
- Neptune, NJ
- Services
- EV Charger Installation, Standby Generator Installation, Standby Generator Service
- Client since
- April 2021
Standby generator
- Manufacturer & model
- Generac 7226
- Rated output
- 18 kW LP / 17 kW NG
- Fuel
- Natural Gas
- Home sized for
- 2,000 sq ft
- Electrical service
- 150 amp
- Transfer switch
- 150 amp
- Load management
- Managed Whole House
- Workmanship warranty
- 5 years
EV charger
- Manufacturer & model
- ChargePoint CPH50-HARDWIRE-L23
- Charging port
- CCS (J1772)
- Circuit breaker
- 60 amp
- Charging stations
- 1
- Estimated range added per hour
- 36 mi / 58 km
Questions from Neptune homeowners
EV chargingWhat should a Neptune homeowner look for in an EV charger installer?
One that treats the charger, the car, the electrical service, the permit and any utility programme as a single system rather than fitting a 60-amp breaker because the charger will take one. That means the household's actual daily driving, what the vehicle's onboard charger accepts, the connector, the service rating, a proper load calculation, the capacity left in the panel, Article 625 and the manufacturer's installation instructions, the correct breaker and conductor sizes, hardwired or plug-in, indoor or outdoor, the municipal permit and final inspection, commissioning and network setup, whatever incentives are open at the time, off-peak charging, how it interacts with solar or back-up power if the house has either, and the second car that may arrive later. The question worth asking is which charging system gives the house the speed it actually needs without upgrading the service unnecessarily.
EV chargingCan a charger be connected to a subpanel?
Yes if the feeder, subpanel, and calculated load can support it. The electrician must consider feeder size, panel rating, available spaces, and total demand.
Standby generatorIs an emergency shutdown required?
The 2023 National Electrical Code contains requirements addressing emergency shutdown of generator prime movers. Whether and how they apply is determined from the generator's rating, its location, the model and the installation, and the factory equipment is evaluated against them rather than presumed to comply.
Standby generatorCan the platform height be read off the FEMA flood map?
Not necessarily. The map matters, but it may not carry every elevation the platform design needs. An Elevation Certificate, a surveyed ground elevation, the Base Flood Elevation, the Design Flood Elevation, the local freeboard and the municipal flood ordinance can all bear on it, so the height is calculated for the specific property.
Standby generatorHow much clearance is needed above a generator?
Applicable air-cooled guidance requires roughly five feet of overhead clearance from structures, overhangs and projections. That is what rules out a good many low decks, roof overhangs and alcoves as generator locations, and it is worth establishing early rather than after a site is chosen.